Authorised to issue certificates for

Class 6
Certified handlers in control of class 6 substances [Regulations 4.1 and 13.9, Health and Safety at Work (Hazardous Substances) Regulations 2017]
 
 
Conditions: The certification of handlers does not include agrichemicals, veterinary medicines, fumigants and vertebrate toxic agents.
 
 
Life cycles: disposal, storage, transport, use

Compliance Plan
Existing Stationary Container Systems for which a compliance plan is in effect [Regulation 17.91 and Schedule 1 Clause 45, Health and Safety at Work (Hazardous Substances) Regulations 2017]

Class 5.2
Locations where class 5.2 substances are present [Regulation 12.42, Health and Safety at Work (Hazardous Substances) Regulations 2017]
 
Classes 2.1.1, 2.1.2 or 3.1
Locations where classes 2.1.1, 2.1.2 or 3.1 substances are present [Regulation 10.34, Health and Safety at Work (Hazardous Substances) Regulations 2017]
 
 
Conditions: The certification of locations where class 2.1.1 substances are present is limited to: packages (cylinders) to a maximum aggregate quantity of 1,000 kg or 1,000 cubic meters (permanent gases); and bulk storage to a maximum aggregate quantity of 5,000 kg.
The certification of locations where class 2.1.2 substances are present is limited to: packages to a maximum aggregate water capacity of 100,000 L.

The certification of locations where class 3.1 substances are present is limited to: storage in closed packages in one or more AS 1940 cabinets to a maximum aggregate quantity of 1,000 L; closed packages with a maximum aggregate quantity of 2,000 L in a store in a building or a maximum aggregate quantity of 10,000 L in a type D store in a building as per Regulation 11.31, Health and Safety at Work (Hazardous Substances) Regulations 2017; closed packages with a maximum aggregate quantity of 10,000 L for storage in a detached building; and bulk storage with a maximum aggregate capacity of 120,000 L.
 
Classes 3.2 or 4
Locations where classes 3.2 or 4 substances are present [Regulation 10.36, Health and Safety at Work (Hazardous Substances) Regulations 2017]
 
 
Conditions: The certification of locations where class 4 substances are present is limited to 500,000 kg.
 
Classes 5.1.1 or 5.1.2
Locations where classes 5.1.1 or 5.1.2 substances are present [Regulation 12.17, Health and Safety at Work (Hazardous Substances) Regulations 2017]

Burners
Stationary Container Systems that include burners [Regulation 17.91(2)(g) and (h), Health and Safety at Work (Hazardous Substances) Regulations 2017]
 
Burning of Class 3.1 substances
Stationary Container Systems that include installations for burning class 3.1 substances [Regulation 17.91(2)(g), Health and Safety at Work (Hazardous Substances) Regulations 2017]
 
Dispensers
Stationary container systems that include dispensers [Regulation 17.91(2)(m), Health and Safety at Work (Hazardous Substances) Regulations 2017]
 
Installation
The installation of Stationary Container Systems [Regulation 17.91(2)(b), Health and Safety at Work (Hazardous Substances) Regulations 2017]
 
 
Conditions: The authorisation for stationary container systems is limited to above ground and below ground tanks up to maximum capacity of 60,000 L (water capacity) per tank used or intended to be used to contain a hazardous liquid.

The authorisation for stationary container systems for above ground tanks and below ground tanks, which have previously been issued certified, is limited to a maximum capacity of 120,000 L (aggregate total) used or intended to be used to contain a hazardous liquid.

The authorisation for stationary container systems does not include the repair, alteration and maintenance of an above ground stationary tank in accordance with API 653 or EEMUA 159 or relevant safe work instrument [Regulation 17.82(1), Health and Safety at Work (Hazardous Substances) Regulations 2017].

The authorisation does not include stationary container systems that include transfer line between ship and stationary tank [Regulation 17.91(2)(i)(iii), Health and Safety at Work (Hazardous Substances) Regulations 2017].

The authorisation for stationary container systems does not include vapourisers [Regulation 17.91(2)(f), Health and Safety at Work (Hazardous Substances) Regulations 2017

The authorisation for stationary container systems does not include a design that is to be certified as per regulation 17.93(1)(a) [Health and Safety at Work (Hazardous Substances) Regulations 2017].

The authorisation of stationary container systems does not include a fabricator for the purpose of constructing a stationary tank or process container in accordance with a design as per regulation 17.93(1)(b) [Health and Safety at Work (Hazardous Substances) Regulations 2017].